Objective
Velamentous cord insertion is an umbilical cord attachment to the membranes surrounding the placenta instead of the central mass. Velamentous cord insertion was associated with adverse perinatal outcomes, most notably pre-term birth and emergency caesarean section in singletons pregnancies and perinatal mortality in twins.
Case(s)
This is a clinical case of a low-risk pregnant woman at 24 weeks of gestation and suspected of having velamentous cord insertion. She did several scans and colour doppler imaging enhances identification of the vessels. The suspicion was in the 12th week of pregnancy. A vaginal birth took place in the 39th week of pregnancy without complications.
Conclusion
Although velamentous cord insertion was suspect before birth, many of its sequelae are only identified in the intrapartum period. The sooner it is suspect and therefore monitored, the better the prognosis.
Keywords
Ultrasonography, doppler, colour, umbilical cord abnormalities
Introduction
Velamentous cord insertion (VCI) is an umbilical cord attachment to the membranes surrounding the placenta instead of the central mass. Because of the lack of protection from Wharton´s jelly, these vessels are prone to compression and rupture, especially when they are located near the cervical ostium (vasa previa), which sometimes coincides.[1,2] The estimated incidence of VCI was 0,4%-11% in singleton pregnancies, with higher incidence in twin pregnancies (1,6%-40%).[1]
VCI was associated with adverse perinatal outcomes, most notably pre-term birth and emergency caesarean section in singleton pregnancies, and perinatal mortality in twins; however, the prenatal diagnosis is based upon the presence of characteristic sonographic findings (membranous umbilical vessels) at the placental cord insertion, this becomes more difficult with advancing gestation.[1,2]
Case
A 32 year old woman, gravid 2, para 1, with a 24 weeks low-risk gestation came to our clinic to have a routine transabdominal ultrasonography with a suspicion velamentous cord insertion (VCI). The fetal growth was normal, the cord seemed to end some centimetres from the placenta, at which point the umbilical vessels separate from each other and cross between the amnio and chorion before connecting to the subchorionic vessels of the placenta (Figure 1), located on the anterior wall. Colour doppler imaging enhances identification of the vessels.[2,4]
The suspicion of VCI was done at 12 weeks gestation scan when the site of placental cord insertion seemed localized at the edge of the placental disk (Figure 2).
She was warned for adverse perinatal outcome (fetal growth restriction, need for caesarean delivery, intrapartum and postpartum bleeding) and was advised pregnancy monitoring more closely.[2-5]
Discussion
Fetal growth was normal and compatible with 12th weeks. She did several scans and the suspicion of VCI was strong in all of them, especially with the use of colour doppler. This clinical information was very important to the clinical team when she was admitted to the hospital in labour at 39th weeks gestation. A vaginal delivery it happened. A female infant was delivered, weighing 3100gr, with Apgar scores of 8 and 9 at 1st and 5th min.
There was no record of neonatal or obstetric complications. After giving birth to the baby, the mother was instructed to expel the placenta, which according to her was like having another birth. A small placenta with VCI were observed (Figure 3). There are no data from large or controlled studies on which to base management recommendations.[1,3]
Conclusion
This case was approached with care in its surveillance, although VCI was suspected before birth, many of its sequelae are only identified in the intrapartum period. Its definitive diagnosis is made by local examination of the placenta, cord and membranes after birth and can have a serious outcome. The sooner it is suspected and therefore monitored, the better the prognosis.